The Actalyke Activated Clotting Time test system takes a bold step forward in the management of heparin anticoagulation. Actalyke analyzers are for use at the point of care during cardiopulmonary bypass, cardiac catheterization, angioplasty, hemodialysis and other procedures where heparin monitoring with accurate ACT results is needed. For enhanced user flexibility and cost-effectiveness. Actalyke instruments and test tubes are interchangeable with other ACT systems using electromagnetic clot detection principles.

Actalyke XL Performance Features
Dual test wells
Dual clot detection
Biological & electronic QC functions
QC functions with lockout option
Three user security levels
Demographic storage
Data storage on disk
Touch screen interface
Optional bar code reader for patient ID entry

Actalyke XL

Cat. No.

Item

 5770

 Actalyke XL Analyzer, 110/220V

 5758

 Actalyke XL Barcode Reader & Cable

 5759

 Actalyke XL Battery Pack

 9133

 Service Manual for Actalyke XL

 1199

 Replacement Agreement for XL Analyzer

 A-PPR

 Actalyke Thermal Printer Paper, 3 rolls

Actalyke Electronic Clotting Tube
 Cat. No.  Item
 XL-ECT  Actalyke Electronic Clotting Tube, 1/pk

The Electronic Clotting Tube is a single device which simulates patient sample clots at three therapeutic heparin levels: 100 seconds (Level I Normal), 300 seconds (Level II Abnormal) and 500 second (Level III Abnormal) for daily quality control of all Actalyke instruments. To ensure consistent and proper instrument operation, this check should be performed once per shift on any shift in which the analyzer is used. The Electronic Clotting Tube features a flashing status indicator when activated as well as low battery indicator.

Actalyke Mini
Easy, one-button operation
Single Test Well
Two-point Clot Detection for Reliability
Accurate
Compact, 6" Footprint
Inexpensive

Cat. No.

Item

5753 Actalyke MINI II Analyzer, 110/220V (w/printer)
5755 Actalyke MINI II Analyzer, 110/220V (without printer)
5763 Actalyke MINI II, 110/220V (with printer and battery)
5765 Actalyke MINI II, 110/220V (with battery)

1197

Comprehensive Replacement for Actalyke MINI Analyzer

9132 Service Manual for Actalyke MINI

9134

Service Manual for Actalyke MINI II

 

2pointTwo-Point Clot Detection System
All premiere Actalyke systems use a two-point clot detection mechanism - one at 0° and another at 90°. This two-point system enables Actalyke to detect a clot at early fibrin formation and is less affected by clot stability. As the clot forms, the magnet travels away from detector 1 toward detector 2. Once it reaches the 46° threshold, the detectors in tandem signify an endpoint. The end result is greater test result reliability, especially on highly heparinized and diluted samples.

MAX-ACT, C-ACT, K-ACT, G-ACT
Helena offers a full line of Actalyke ACT tubes, including traditional glass bead, kaolin, celite plus new MAX-ACT. MAX-ACT uses a blend of celite, kaolin and glass bead. Factor XII has been found to be multi-species in nature and may not be fully activated by one type of activator. By using a cocktail of activators, MAX-ACT provides maximal activation of Factor XII resulting in greater heparin specificity and exceptional linearity.

New MAX-ACT
Full Activation, Greater Specificity

lg heparin
Blend of Activators - celite, kaolin & glass bead -
   for full activation and greater heparin specificity
Improved linearity - up to 6 units heparin/mL blood
Actalyke with MAX-ACT tubes offer best precision, lowest CVs and greatest heparin specificity

Actalyke ACT Reagent Tubes

 Cat. No.

 Item

 Description

 MAX-ACT

 MAX-ACT Reagent Tubes

 50 tubes/box

 G-ACT

 Glass Bead ACT Reagent Tubes

 50 tubes/box

 K-ACT

 Kaolin ACT Reagent Tubes

 50 tubes/box

 C-ACT

 Celite ACT Reagent Tubes

 50 tubes/box


 
 
 
 
 
AQC-HP Control Kit for MAX-ACT, C-ACT, K-ACT
Cat. No. Item
AQC-HP QC Kit 1 Normal, 1 High Control
10 x 1 mL QC Level - I
10 x 1 mL QC Level - III
2 x 11 mL Diluent
2 x 11 mL Calcium Chloride
The QC Kit is for use in verifying reagent performance with MAX-ACT, C-ACT and K-ACT Tubes. The kit provides two levels of quality control, normal and high. The lyophilized control is stable one hour at room temperature once reconstituted.
 

AQC-LP Control Kit for G-ACT
Cat. No. Item
AQC-LP G-ACT QC Kit 1 Normal, 1 Low Control
10 x 1 mL QC Level - I
10 x 1 mL QC Level - II
2 x 11 mL Diluent
2 x 11 mL Calcium Chloride
The G-ACT QC Kit is for use in verifying reagent performance with Glass Bead ACT (G-ACT) Tubes. The kit provides two levels of quality control, normal and low. The lyophilized control is stable one hour at room temperature once reconstituted.