Actalyke XL Performance Features
• Dual test wells
• Dual clot detection
• Biological & electronic QC functions
• QC functions with lockout option
• Three user security levels
• Demographic storage
• Data storage on disk
• Touch screen interface
• Optional bar code reader for patient ID entry
Actalyke XL
Cat. No. |
Item |
5770 |
Actalyke XL Analyzer, 110/220V |
5758 |
Actalyke XL Barcode Reader & Cable |
5759 |
Actalyke XL Battery Pack |
9133 |
Service Manual for Actalyke XL |
1199 |
Replacement Agreement for XL Analyzer |
A-PPR |
Actalyke Thermal Printer Paper, 3 rolls |
Actalyke Electronic Clotting Tube
| Cat. No. | Item |
| XL-ECT | Actalyke Electronic Clotting Tube, 1/pk |
The Electronic Clotting Tube is a single device which simulates patient sample clots at three therapeutic heparin levels: 100 seconds (Level I Normal), 300 seconds (Level II Abnormal) and 500 second (Level III Abnormal) for daily quality control of all Actalyke instruments. To ensure consistent and proper instrument operation, this check should be performed once per shift on any shift in which the analyzer is used. The Electronic Clotting Tube features a flashing status indicator when activated as well as low battery indicator.
Actalyke Mini
Easy, one-button operation
Single Test Well
Two-point Clot Detection for Reliability
Accurate
Compact, 6" Footprint
Inexpensive
Cat. No. |
Item |
| 5753 | Actalyke MINI II Analyzer, 110/220V (w/printer) |
| 5755 | Actalyke MINI II Analyzer, 110/220V (without printer) |
| 5763 | Actalyke MINI II, 110/220V (with printer and battery) |
| 5765 | Actalyke MINI II, 110/220V (with battery) |
1197 |
Comprehensive Replacement for Actalyke MINI Analyzer |
| 9132 | Service Manual for Actalyke MINI |
9134 |
Service Manual for Actalyke MINI II |
Two-Point Clot Detection System
All premiere Actalyke systems use a two-point clot detection mechanism - one at 0° and another at 90°. This two-point system enables Actalyke to detect a clot at early fibrin formation and is less affected by clot stability. As the clot forms, the magnet travels away from detector 1 toward detector 2. Once it reaches the 46° threshold, the detectors in tandem signify an endpoint. The end result is greater test result reliability, especially on highly heparinized and diluted samples.
MAX-ACT, C-ACT, K-ACT, G-ACT
Helena offers a full line of Actalyke ACT tubes, including traditional glass bead, kaolin, celite plus new MAX-ACT. MAX-ACT uses a blend of celite, kaolin and glass bead. Factor XII has been found to be multi-species in nature and may not be fully activated by one type of activator. By using a cocktail of activators, MAX-ACT provides maximal activation of Factor XII resulting in greater heparin specificity and exceptional linearity.
New MAX-ACT
Full Activation, Greater Specificity

Blend of Activators - celite, kaolin & glass bead -
for full activation and greater heparin specificity
Improved linearity - up to 6 units heparin/mL blood
Actalyke with MAX-ACT tubes offer best precision, lowest CVs and greatest heparin specificity
Actalyke ACT Reagent Tubes
Cat. No. |
Item |
Description |
MAX-ACT |
MAX-ACT Reagent Tubes |
50 tubes/box |
G-ACT |
Glass Bead ACT Reagent Tubes |
50 tubes/box |
K-ACT |
Kaolin ACT Reagent Tubes |
50 tubes/box |
C-ACT |
Celite ACT Reagent Tubes |
50 tubes/box |
| Cat. No. | Item |
| AQC-HP | QC Kit 1 Normal, 1 High Control |
| 10 x 1 mL QC Level - I | |
| 10 x 1 mL QC Level - III | |
| 2 x 11 mL Diluent | |
| 2 x 11 mL Calcium Chloride | |
| Cat. No. | Item |
| AQC-LP | G-ACT QC Kit 1 Normal, 1 Low Control |
| 10 x 1 mL QC Level - I | |
| 10 x 1 mL QC Level - II | |
| 2 x 11 mL Diluent | |
| 2 x 11 mL Calcium Chloride | |
![]() |
|||||||||||
|
|
|
|
|||||||||
|
|
|
|
|
|
|||||||
|
|
![]() |
|
|||||||||
![]() |
|
||||||||||
![]() |
![]() |
||||||||||
![]() |
![]() |
||||||||||
|
|
![]() |
![]() |
![]() |
||||||||
![]() |
|||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|