AggRAM
Advanced Modular System for Platelet Aggregation Ristocetin Cofactor

Cat. No.

Item

1484

AggRAM Analyzer

1486

AggRAM Module

The AggRAM, for platelet aggregation and ristocetin cofactor testing offers unsurpassed precision, ease of use and flexibility. AggRAM couples four-channel laser optic modules with a powerful Windows interface. Up to two modules can be run per Remote Analyzer computer, providing up to eight channels to handle your workload.

Advanced Laser Optics
Unlike the tungsten lamp optics of old, the AggRAM uses a laser diode to provide beautiful precision across all channels. Upon start-up, AggRAM performs a laser balance check to ensure reproducibility day to day, year to year. Advanced optics coupled with an improved algorithm for slope calculation greatly improve precision for ristocetin cofactor testing.

Powerful, User-Friendly Interface
The AggRAM system software takes full advantage of the Windows platform. On-screen prompts step users through testing. The ability to open multiple windows greatly increases efficiency. For instance, watch the channel display in real time in one window while starting a new worklist in another. Open a third window and print previous runs or observe any combination of channels. Additional features include:

Three levels of password protection, from user to administrator
Quick access to data input screens
Barcode and bi-directional LIS capable

Data Handling Features
Automatically calculates slope and max % aggregation; displays and print lag phase; automatically calculates curves and smooths; reference overlay

Customized Reports
Includes data from one channel or four, one patient or the whole run; pulls from data archives to profile patient results over time.

 

Quality Control
Evaluates and charts QC for ristocetin cofactor based on Westgard rules; generates Levy-Jennings charts, standard curves, etc with an integral action log.


AggRAM™ Specifications
Test Types: Platelet Aggregation and Ristocetin Cofactor
Absorbance Range: 0.0 to 2.0 O.D.
Measuring Wavelength: 650 nm
Optical Chambers per module: Four chambers for combined or individual measurements
Cuvettes: 8 mm x 60 mm (silicone coated glass)
Stir Bars: 3.5 mm x 4 mm (coated magnet)
Incubation and Reaction Temperature: 37°C +/-1°C
Graphs: -20% to 110% activity (+/- 0.5%) versus time
Instrument Operating Environment: Ambient Temperature Range 15° to 30°C (59° to 86°F)
Module:
Input Power: 110/220 Vac, 50/60 Hz, 1200 Watts Maximum
Dimensions: 6" (15.24 cm) Tall x 10" (25.40 cm) Wide x 17" (43.18 cm) Deep
Weight: < 15 lbs (6.75 kg)
Computer:
800 MHz or higher processor (Intel Pentium/Celeron family)
64 MB or higher of RAM
1.5 GB of available hard disk space
Microsoft® Windows® 2000 Operating System
CD-RW drive
Super VGA (800 x 600) or higher resolution video adapter monitor.
Keyboard and Mouse.
Hp Deskjet 6122 Printer.


AggRAM Accessories and Supplies
1473 Siliconized Curvettes for AggRAM and PACKS-4, 200/pkg

1479

Scale Set Solutions (650 nm) for Platelet Assays, 1 each Low and High Calibrator

1489 AggRAM Stir Bars, 30/pkg
9139 Service Manual for AggRAM

Platelet Aggregation Reagents
5366 ADP, 2 x 1 mL
5367 Epineprhine, 2 x 1 mL
5368 Collagen, 2 x 1 mL
5369 Platelet Aggregation Kit (5366, 5367, 5368)
5199 Ristocetin (for RIPA), 10 x 0.5 mL
5365 Tris-Buffered Saline, 1 x 125 mL

Ristocetin Cofactor Reagents
5370 Ristocetin Cofactor Kit, 60 tests
5371 Lyophilized Platelets, 5 x 5 mL
5373 Risto Cofactor Abn Control, 5 x 0.5 mL
5372 Ristocetin (10 mg/mL), 5 x 1.5 mL
5365 Tris-buffered Saline, 1 x 125 mL
5356 Lyophilized Platelets, 5 x 10 mL

 


PACKS-4 Accessories and Replacement Parts

 Cat. No.

Item

 1463

Air Filters for PACKS-4, 3/pkg

 1473

Siliconized Cuvettes for AggRAM and PACKS-4, 200/pkg

 1474

PACKS-4 Stir Bars, 30/pkg

 1481

PACKS-4 Micro Volume Pipettor (5, 10, 25 µL)

 1482

PACKS-4 Pipettor (50, 75, 100 µL)

 1475

Disposable Pipette Tips (50-200 µL), 1000/pkg

 1476

Disposable Pipette Tips (100-1000 µL), 1000/pkg

 1477

PACKS-4 Replacement Lamp, 1/pkg

 1478

4-Color Printer Cartridge for Citizen printers

 1479

Scale Set Solutions (650 nm) for Platelet Assays, 1 each Low and High Calibrator

 1480

Scale Set Solutions (405 nm) for Chromogenics, 1 each Low and High Calibrator 

 1485

Black Printer Cartridge for Citizen printers 

 